TECHNICAL RESOURCES · ENERGY MEASUREMENT
How to measure energy consumption
in an injection-moulding cell.
Equipment boundaries, measurement periods and production data for meaningful energy comparisons.
When auxiliary equipment has separate electrical supplies, the injection-moulding machine accounts for only part of the cell’s total consumption. Before comparing results, identify each item of equipment and check how it is electrically connected.
1. Identify the equipment to be measured.
List the injection-moulding machine and the auxiliaries you intend to measure: dryer, temperature controller, chiller and any other equipment. Check which units have their own supply and which are already included in the machine’s incoming feed.
Do not add the reading of a whole supply to the reading of a device powered by that same supply: this would double-count some energy. Shared utilities serving several machines require a documented allocation method.
2. Distinguish power from energy.
Power, in kW: the rate at which electrical energy is used at a given moment. Energy, in kWh: the amount of electrical energy consumed over a period.
At constant power, energy = power × time. When power varies, as it does during injection moulding, energy is obtained by integrating the measured power over time.
3. Record when production takes place.
Identify start-up, production, product changeovers, idle periods and stops. Consumption during a pause does not automatically mean waste: some equipment must maintain process conditions. Consider each unit’s function and the operating procedure.
4. Compare equivalent operating conditions.
- The same equipment included in the measurement.
- Clearly identified periods with known durations.
- Product, material, mould and quantity produced.
- Start-up conditions, settings and downtime.
- Consistent criteria for counting accepted parts, rejected parts or processed mass.
Lower total energy consumption may simply reflect lower output. A before-and-after comparison therefore needs both kWh and production quantities, together with the conditions of each period.
5. Calculate indicators using matching datasets.
kWh per cycle = energy consumed during the period ÷ cycles completed during the period.
kWh per part = energy consumed during the period ÷ parts counted during the same period.
kWh per kg = energy consumed during the period ÷ the mass defined for that same period.
State whether the part count includes all parts or only accepted parts, and whether mass means processed material or accepted product. The denominator must be greater than zero. Without reliable output data, report total energy and measurement duration instead.
ILLUSTRATIVE CALCULATION
120 kWh ÷ 6,000 accepted parts = 0.020 kWh per accepted part.
Illustrative example; no customer data are used. The 120 kWh and 6,000 accepted parts must refer to the same period and defined equipment boundary. This calculation alone does not demonstrate savings.
Machine or Cell: what should you measure?
Energy: Machine measures a machine, a defined electrical feed or a major load. Energy: Cell measures the injection-moulding machine and selected auxiliaries simultaneously to analyse the distribution of energy consumption.
TECHNICAL REVIEW
Dr.-Ing. Miguel Garzón · Technical Director, KERN IoP
Reviewed by the technical management of KERN IoP, a division of PM Tec Engineering. Last reviewed: October 2026. Technical profile and publications →
Engineering
Resources
PM Tec Engineering, through its Industry 4.0 division, KERN IoP.
Cota, Cundinamarca · Colombia.
© 2026 PM Tec Servicios de Ingeniería SAS · Website updated in 2026.