KERN IoP | ENERGY · REAL-TIME ENERGY MONITORING

Understand your machine’s energy behaviour during production.

Understand when, how much and how your machine consumes energy. Identify periods of higher demand, unusual consumption patterns and opportunities for improvement to control energy costs and produce each part more efficiently.

Active power

Real-time power

Accumulated electrical energy

Consumption and historical data

Power curve

Changes in operating behaviour

KERN IoP Energy dashboard on a monitor in an industrial plastics processing plant.
Interface shown in Spanish.

KERN IoP | ENERGY: energy measurements, historical data and equipment breakdowns for operating analysis.

DATA FOR UNDERSTANDING MACHINE OPERATION

Use electricity consumption data to understand machine operation.

Energy demand changes with the machine’s operating state. Historical power and energy records reveal patterns, support comparisons and identify deviations requiring investigation.

KERN IoP | ENERGY makes this information available to production, maintenance and engineering teams so they can examine machine behaviour, identify anomalies and base decisions on recorded measurements.

Engineer using KERN IoP | ENERGY on a tablet to analyse a production machine’s energy consumption in real time.
Real-time energy monitoring for analysing machine behaviour during production. Interface shown in Spanish.

CONTINUOUS VISIBILITY

Examine energy behaviour

Observe power and energy consumption during operation and retain historical records for analysis.

OPERATING CHANGES

Identify deviations earlier

Identify increases, decreases or unusual patterns and focus investigations on the relevant periods.

OPERATING CONTEXT

Understand downtime and low-activity periods

Examine energy use before, during and after a stoppage or change in operation.

KERN IoP | ENERGY / PLANT APPLICATION

Define the equipment included in the measurement before installation.

Identifying electrical feeds to the injection-moulding machine and selected auxiliaries helps define a consistent measurement configuration. Instrumentation is specified according to the electrical circuits and actual plant operation.

01 / MACHINE

Moulding-machine electrical supply

Identify voltage, phases, circuit and operating conditions associated with the machine.

02 / AUXILIARIES

Cell electrical connections

Specify which drying, mould-temperature control and cooling equipment should be measured separately.

The same technical question may be addressed by measuring one machine or several independent feeds within a cell.

Define my configuration →

THE TECHNICAL QUESTION DEFINES THE SCOPE

Measure one machine, incorporate production data or extend the scope to the complete cell.

KERN IoP | ENERGY can begin with a single measurement point and expand as analytical needs evolve. The electrical architecture, production data and available signals determine which indicators are possible.

Icon of an injection moulding machine with energy measurement, on a transparent background.

01 / MACHINE

One electrical feed, one defined reference.

To examine a machine’s consumption, establish an energy baseline or track changes in electrical behaviour.

Configure measurement →

Icon of process energy curves with a lightning bolt, on a transparent background.

02 / PROCESS

Energy measurements linked to cycles and production.

By integrating product reference, mass, quantities or cycle signals, the measurements can be expressed as kWh/kg, kWh/part or energy per cycle.

Explore the process signature ↓

Icon showing three electrical feeds, on a transparent background.

03 / CELL

Distinguish the machine from its auxiliaries.

Measure several three-phase or single-phase feeds and compare each load’s contribution to the instrumented cell’s total consumption.

Explore ENERGY: Cell →

INTERPRETING ENERGY MEASUREMENTS

Power, energy and electrical feeds: three different dimensions.

Electrical meter with a lightning bolt and power pointer, representing active power.

Power by electrical feed

Instantaneous power in kW helps identify changes and peaks during operation.

Accumulated energy meter with an electrical symbol.

Energy over a time interval

kWh indicates accumulated energy consumption for each individually instrumented feed.

Three independent electrical feeds measured separately.

Defined electrical measurement boundary

Only independently measured electrical feeds can be distinguished within a cell. The three phases of one supply are not three different pieces of equipment.

Icon of electrical energy per mass produced: a lightning bolt and a digital scale holding a plastic part.

Production-related energy indicator

kWh/kg or kWh/part also requires reliable production data over a matching time interval.

POWER QUALITY · BEYOND kWh

When a machine stops, the electrical supply may also matter.

A voltage dip, phase imbalance or abnormal peak may be brief and disappear before maintenance personnel arrive. Continuous monitoring preserves the electrical context of the stoppage.

With KERN IoP | ENERGY, the electrical feed is documented beyond its accumulated consumption: measured voltage, phase data, power and energy can be compared with production events when these records are available.

THE ENGINEERING QUESTION

Beyond “how much was consumed?”: “what happened electrically when the machine stopped?”

Injection moulding machine with an installed mould and KERN IoP SMARTPRO mounted beside the machine controls.
KERN IoP | SMARTPRO for relating electrical measurements to operating conditions.
KERN IoP | ENERGY dashboard showing power, line voltage and current per phase for a three-phase installation on an injection moulding machine.
Recorded power, line voltage and phase currents for analysing electrical behaviour.

Five electrical signals and patterns worth recording.

01 · VOLTAGE

Dips and variations

Examine voltage deviations and compare timestamps with machine alarms, restarts or stoppages.

02 · PHASES

Phase imbalance

Where the instrumentation provides phase-specific values, compare voltage and current. Sustained imbalance warrants investigation because it can increase losses and heating in three-phase loads.

03 · DEMAND

Power peaks

Identify when demand peaks and which equipment was running. Historical records help distinguish recurring peaks from unusual events.

04 · MAINTENANCE

Consumption that deviates from normal

If a machine begins drawing more power than its historical baseline under comparable conditions, that deviation may justify inspection. Energy data alone cannot diagnose a failure, but can guide investigation.

05 · TRACEABILITY

Historical evidence rather than recollection

Retain timestamped measurements to investigate recurring events, compare shifts and correlate electrical changes with production. Formal power-quality assessments and disputes require applicable metrological and regulatory provisions.

FROM EVENT TO TESTABLE HYPOTHESIS

1. Detect the electrical deviation

→

2. Correlate time, machine and operating state

→

3. Decide whether to investigate the supply, machine or process

Technical note. IEC 61000-4-30 specifies measurement methods for power-quality phenomena such as voltage magnitude, dips, swells, interruptions and imbalance. Operational monitoring by KERN ENERGY is not automatically equivalent to a Class A study; event characterisation depends on the selected instrumentation and resolution.

IEC 61000-4-30 ↗  ·  DOE · Voltage Unbalance ↗  ·  CREG · Power quality ↗

PROCESS SIGNATURE · POWER VS TIME

The energy profile of a cycle has a distinctive shape.

With sufficiently time-resolved power measurements aligned with the cycle, a process signature can be created: a curve for comparing changes in electrical demand between manufacturing conditions.

Comparisons must use stable runs under documented conditions. The power profile complements, but does not replace, product-quality assessment.

Electrical power over time.

ONE PART · TWO PROCESS CONDITIONS

Compare the baseline with an adjusted process.

PROCESS PHASES THAT CAN BE IDENTIFIED WHEN THE REQUIRED SIGNALS ARE AVAILABLE

Clamping

Injection

Holding pressure

Plasticising

Cooling

CONDITION A · BASELINE

Energy per cycle, cycle time and documented quality.

CONDITION B · ADJUSTMENT

Repeat the measurement and compare differences under equivalent conditions.

ENERGY · FURTHER READING

What should be analysed after measurement?

Electrical measurements show power and energy at a particular point. Interpreting the process also requires knowing the product being manufactured and the equipment’s operating state.

How much energy does the cell consume while idle?

Distinguish moulding-machine and auxiliary-equipment operating states using records from the measured interval.

Does the measurement cover the machine or the complete cell?

Define the measured circuits before attributing consumption to equipment or products.

Which data does management need for cost analysis?

Relate energy, time and capacity to actual manufacturing conditions.

USING THE DATA

Information for production teams.

01

Breakdown by equipment

Distinguish the signals from electrical loads included in the measurement scope.


02

Activity outside production

Observe persistent power demand during idle periods; classifying the operating state requires additional signals or records.


03

Comparison of periods

Document a baseline and compare equivalent periods after an operating change.

BY AREA OF RESPONSIBILITY

One measurement supports different technical questions.

Plant management

Which cell warrants further analysis before investment?

Energy management

Which point consumes how much energy, and when?

Process engineering

How did power and energy change after the process adjustment?

SUSTAINABILITY · CO₂e · ISO 50001

Industrial sustainability supported by energy data.

Continuous kWh recording provides a quantitative basis for industrial sustainability, energy-efficiency and environmental-monitoring initiatives. Historical data support comparisons of energy performance over time and estimates of emissions in CO₂e using emission factors and documented assumptions.

ISO 50001:2018 provides a framework for implementing and improving an energy management system, addressing energy performance, efficiency, use and consumption. KERN IoP | ENERGY historical records can support monitoring of energy performance indicators, baselines and company-defined improvement objectives.

For product carbon footprints or other environmental inventories, energy records may be combined with production data, emission factors and an appropriate methodological boundary.

Industrial sustainability concept with green leaves, water, an industrial plant and a CO2e symbol for energy and emissions analysis.
Energy data can support sustainability indicators, energy-performance metrics and CO₂e estimates.

Energy performance

Use, consumption and comparable historical records

CO₂e

Estimates using documented emission factors

ISO 50001

Energy monitoring and continual improvement

EXPAND THE MEASUREMENT SCOPE

Understand the energy consumption associated with each product

If you need indicators such as kWh/kg, kWh/part or energy per cycle, KERN IoP can complement electrical measurements with sensors, data-acquisition systems and software to integrate production information in real time.

Depending on the application, quantities produced, part weight, product reference, machine states and cycle signals can be integrated. Relating them to energy consumption enables comparisons between products, machines, shifts and process conditions.

The system can be extended with KERN IoP | SMARTPRO, additional instrumentation and KERN IoP monitoring and analysis tools, bringing energy, production and process information together on one platform.

PRODUCTION + PROCESS + ENERGY

KERN IoP SMARTPRO displaying operating status, product reference and production data in real time.
Interface shown in Spanish.

Production data can form part of the same architecture.

SMARTPRO allows operating and production data to be combined with machine signals and other available variables. KERN IoP can specify suitable instrumentation and software for each application.

kWh/part

Per product

kWh/kg

Per mass processed

kWh/cycle

Per production cycle

EUROMAP 60 · DEFINE THE MEASUREMENT BOUNDARY

The same kWh/kg figure can answer different questions.

EUROMAP 60 distinguishes machine-related assessment from measurements for a specific product and process. This is important when defining what to measure before interpreting specific energy consumption.

EUROMAP 60.1 · MACHINE RELATED

When assessing the machine’s energy efficiency.

It defines a classification using specific energy consumption and idle-state measurements to describe injection-moulding machine efficiency under comparable conditions, seeking to isolate influences of the mould and customer application.

  • Useful for comparing machines of similar sizes.
  • Excludes, among other things, auxiliaries, material transport and energy for mould cooling.
  • The measurement boundary focuses on the basic machine.

Read EUROMAP 60.1 ↗

EUROMAP 60.2 · PRODUCT RELATED

When determining the energy needed to produce a part.

It defines electrical energy consumption for a particular machine producing a particular product using a particular process. Consumption is divided into defined blocks and product and process conditions must be documented.

  • Includes machine/control and heating; other blocks depend on the documented scope.
  • Certain auxiliaries may be included as optional blocks.
  • Relates energy consumption to product, mass, cycle and manufacturing conditions.

Read EUROMAP 60.2 ↗

Where does KERN IoP fit?

The architecture can instrument a single feed or several circuits in a cell and, when production data are integrated, associate energy with kilograms, parts or cycles. Formal application of EUROMAP 60.1 or 60.2 requires complying with the recommendation’s conditions, boundaries and instrumentation. A monitoring installation is not automatically equivalent to a EUROMAP test.

SERVICE · PROCESS ENERGY OPTIMISATION

Optimise processes to reduce energy per part.

PM Tec Engineering, through its Industry 4.0 division KERN IoP, offers optimisation studies based on an initial operating condition. Equivalent cycles are compared and process adjustments evaluated to reduce energy per cycle and, where technically possible, cycle time.

Product quality and process stability are evaluated in each comparison. Optimisation aims for a documented condition combining energy efficiency, cycle performance and compliance with product specifications.

Power curve used to compare process conditions.

01 · MEASURE

Establish the baseline

Record stable cycles and document machine, mould, material, parameters and quality.

Injection moulding cycle time.

02 · OPTIMISE

Evaluate adjustments

Identify a more efficient condition within the permitted process window and quality criteria.

Specific energy consumption.

03 · VERIFY

Compare the results

Compare energy per cycle, cycle time and quality variables under equivalent conditions.

Improvement potential depends on the baseline, material, mould, machine and available optimisation margin. Measurement and verification quantify the results achieved.

Technical reading: energy during an injection-moulding cycle

Measuring energy through the cycle phases helps compare processing configurations under equivalent conditions. Laura Flórez presents a KERN IoP application and discusses analysis of energy curves in Plastics Engineering (SPE, 2024).

Read “Two Ways to Reduce Energy Consumption in Injection Molding” in Plastics Engineering ↗   ·   Other publications by Laura Flórez →

SPECIALIST MEDIA COVERAGE

KERN IoP energy monitoring featured in Tecnología del Plástico

The industry publication discusses five approaches to improving energy efficiency in plastics processing and includes KERN IoP’s energy-monitoring solution.

FREQUENTLY ASKED QUESTIONS · KERN IoP | ENERGY

Answers about industrial energy monitoring.

These are common questions when evaluating energy measurements for a machine or production cell.

What does KERN IoP | ENERGY measure?

It records electrical power and energy of the instrumented feed and, depending on configuration, variables such as voltage and current per phase for analysing machine electrical behaviour.

Can it measure a three-phase electrical feed?

Yes. Instrumentation is configured for the electrical installation and can retain historical measurements for all three phases.

How can it help control production costs?

Historical records identify periods of high power demand, waiting, stoppages and changes in operating behaviour. These data help focus energy-efficiency actions and verify their effects.

Can kWh/kg, kWh/part or energy per cycle be calculated?

Yes. When electrical and production data are integrated, KERN IoP can associate consumption with processed mass, parts produced or cycles to calculate application-specific indicators.

What is the difference between ENERGY and ENERGY: Cell?

KERN IoP | ENERGY can begin by measuring one machine’s electrical feed. KERN IoP | ENERGY: Cell extends the scope to distinguish several independent connections in a cell, such as the moulding machine and selected auxiliaries.

How can it support energy management aligned with ISO 50001?

Historical energy records can support monitoring of performance indicators, baselines and energy-improvement objectives defined within an organisation’s energy management system. Read our technical guide to ISO 50001, submetering and energy analysis →

Configure KERN IoP | ENERGY for your machine.

Tell us about the machine’s electrical supply and your measurement objectives. Our team will review the application and propose a suitable instrumentation and monitoring configuration.


PM Tec Engineering, through its Industry 4.0 division, KERN IoP.
Cota, Cundinamarca · Colombia.
© 2026 PM Tec Servicios de Ingeniería SAS · Website updated in 2026.

Privacy and Personal Data Processing Policy